Description​

The Modbus adapter allows to connect to a PLC using the Modbus specification.


Configuration​

The following configuration options are available when creating the adapter:

PLC Address​

The IP address of the Modbus device without any prefix, which will be added automatically when creating the adapter.

PLC Port​

The PLC port refers to the port of the PLC, such as 502.

Node ID​

The Node ID refers to the ID of the specific device.

Nodes​

The Nodes section requires configuration options for the individual nodes. Nodes can be either imported from a comma-separated CSV file, or can be directly assigned in the configuration menu.

The following fields must be provided for each node:

  • Runtime Name: Refers to the field to internally identify the node, e.g., in the data explorer or pipeline editor.
  • Node Address: Refers to the address of the Node in Modbus, e.g., 1
  • Object Type: Can be selected from the available options DiscreteInput, Coil, InputRegister, or HoldingRegister.

An example CSV file looks as follows:

Runtime Name,Node Address,Object Type,
field1,1,Coil
temperature,2,Coil

Note that the CSV header must exactly match the titles Runtime Name, Node Address and Object Type.